To program effectively, the case history is not as important as the audiometric battery.
The style of hearing instrument must be determined by the patient.
Programming begins with the following.
The average volume of the ear canal is _____ cc.
An average earmold takes up about _____ cc.
Equipment to analyze hearing instrument performance in vivo and in situ is called:
Reference sound pressure level refers to _____ mPa or _____ dynes/cm squared.
Input sound pressure level is the sound at the _____.
Acoustic gain is the difference between the output SPL and the input SPL in the 2 cc coupler.
Manual gain control is another term for the _____.
A directional HI is a _____ instrument dependent on the incoming direction of sound.
SSPL 90 is the abbreviation for Saturation Sound Pressure Level for a 90 decibel _____.
The SSPL 90 is determined when the volume control is _____.
The SSPL 90 displays the _____ sounds the hearing instrument can produce across the frequency spectrum of that hearing instrument.
In the output/gain/slope matrix, the SSPL 90 relates to the UCL and is the _____ number in the ITE and canal matrix.
When the volume control is full on and the input is 60 dB SPL, term for this test is _____.
In the matrix, this is the _____ number.
High frequency Average FOG is the high frequency average full on gain at which frequencies?
Average speech dB SPL is approximately _____ dB SPL.
A linear hearing instrument in at _____ with the VC set full on.
A reference test position is used with _____ hearing instruments.
The reference test gain position is different from the reference test position. The Reference Test Gain position is _____ dB SPL.
The frequency response curve for AGC HIs is done with the RTP at _____ dB SPL.
Battery current measurements are taken with a 1000 pure tone 65 dB input signal at the _____.
Programming begins by selecting the _____ formula options avaliable on the software.
Begin programming by running the _____ automatic measurement in total quiet.
Is the first fit option on the software the final fit?
Which of the following are examples of troubleshooting?
Troubleshooting deals with _____.
The main enemies of hearing aid performance are: (check all that apply)
Most troubleshooting can be prevented by _____.
When troubleshooting, the first step you take is to _____.
To program effectively, the case history is not as important as the audiometric battery.
Check for the following when troubleshooting.
A common trouble spot is a _____.
A weak battery can lead to the following results:
If you turn the instrument onto the telecoil position, the receiver is functioning if you hear amplification. Switching to the Microphone position, if you do not hear amplification, the microphone is defective/nonfunctional.
Feedback can be due to: